This vent kit is to be used with 2 vent systems.
Direct vent furnace sidewall vent kit.
Next b vent is for negative pressure draft systems only.
It also has a more attractive appearance on the outside of the building.
Direct vent furnace side wall vent kit 0170k00001s.
The vent kit must terminate outside the structure and may be installed with the intake and exhaust pipes located side by side or with one pipe above the other.
Do not use for roof top venting use this kit for side wall venting only.
Do not use this kit to vent category i ii or iii furnaces do not apply to non condensing furnaces.
The space saving direct vent furnace design mounts to an exterior wall and the adjustable vent assembly adjusts to fit walls from 4 1 2 in.
The 2 3 side wall direct vent kit is for use with high efficient condensing furnaces.
Direct venting uses a power ventilating blower or fan and in some models a heat exchanger plenum to cool outgoing gases passing through the building wall sidewall direct exhaust or roof or through an existing unused chimney through which a vent pipe is passed vertical direct exhaust.
Air necessary for combustion is drawn into the.
Warning do not use the concentric vent kit for anything other than a category iv furnace.
A sidewall power venter can be installed.
Vent kit is not for use with single pipe indirect vent installations.
So even if your furnace were to be approved for side wall venting b vent is not the proper type of vent pipe to use.
It provides an alternative to the traditional two pipes out the wall option.
I0 635a september 2013 warning this vent kit is only to be used for venting category iv condensing furnaces.
Cvent 3 is for use with 3 in.
The vent kit must terminate outside the structure and can be installed with the intake and exhaust pipes located side by side or with one pipe above the other.
B vent is not airtight.
Failure to follow this warning could result in fire personal injury or death.
Combustion products are discharged outdoors through the wall vent.
All vent caps include a built in bird guard.
Direct vent counterflow the forced air circulation comfort heating system uses only outside air for combustion as the burners are completely sealed within the combustion chamber.
For use with direct vent furnace side wall vent kit function this vent kit is only to be used for venting category iv condensing furnaces do not use this kit to vent category i ii or iii furnaces do not apply to non condensing furnaces do not use for roof top venting how can we improve our technical specifications.
This kit is not intended for use with single pipe indirect vent installations.
Refer to the furnace installation instructions for intake vent pipe sizing information.
The york etc used a stainless flex pipe and not b vent.